现场常见问题
The server-room AC dies on Friday night and nobody knows until Monday morning. A vaccine fridge climbs above 8°C during a night-time power cut. Rainwater seeps into the basement electrical room. All of it is preventable if someone finds out within five minutes, not two days.
What can be measured
| Sensor | Example use |
|---|---|
| Temperature / humidity | Server rooms, cold rooms, medicine and vaccine fridges (2–8°C) |
| Water leak | Under AC units, raised floors, electrical rooms |
| Door / motion | Racks, storerooms |
| Power / energy | Current, voltage, consumption (kWh) |
| Air quality | CO2 and PM2.5 in offices and schools |
Pick the right technology for the site
- Wired/PoE and SNMP: for server rooms (e.g. environmental monitors from UPS vendors)
- LoRaWAN: long range and multi-year battery life for factories and large sites. Sensors and gateways are built for a specific band; for Laos that is usually the AS923 plan, which we confirm before ordering
- Wi-Fi / 4G: for scattered points with no gateway nearby
Platform and alerting
Everything lands in one dashboard (e.g. Zabbix or a chosen IoT platform) with history graphs. Alerts escalate: the on-call person first, then the manager if nobody acknowledges within 15 minutes. They go out over the channels the team actually reads: SMS, LINE, Telegram or WhatsApp, as the platform supports. Don't set thresholds too tight. If phones buzz every ten minutes, people stop reading them.
Tell us how many points you want to watch and where, and we will recommend sensors and the right way to connect them.
功能
Instant alerts
SMS, LINE, Telegram or email when thresholds are crossed.
Multi-step escalation
Escalates if nobody acknowledges.
History & reports
Historical graphs for audits such as medicine-fridge temperature logs.
Long-range LoRaWAN
Multi-year battery sensors covering large areas.
Energy monitoring
Sub-metering to find where energy is wasted.
UPS & cooling integration
UPS status via SNMP in the same dashboard.
设计与实施
- 1
Identify risk points and the thresholds to watch.
- 2
Select sensors and connectivity (SNMP, LoRaWAN, Wi-Fi, 4G).
- 3
Install sensors, gateways and the platform.
- 4
Configure alert rules, escalation and channels.
- 5
Test each scenario for real (switch off the AC, wet the leak sensor) and train the response team.
适用场景
- Server rooms and branch network cabinets.
- Hospitals and pharmacies monitoring medicine and vaccine fridges.
- Cold storage and food processing plants.
- Schools and offices tracking CO2 and PM2.5 during burning season (February–April).
常见系统规模
我们供货并安装的品牌
所有品牌名称和商标归其各自所有者所有。除非另有明确说明,提及某品牌并不代表与其存在合作关系。产品均通过正规分销渠道采购。
常见问题
Will alerts work if the internet is down?
For critical sites, use a device with a GSM modem that sends SMS directly or a 4G backup path, and put it on UPS too. Otherwise the alerting dies first when the power does.
How long do wireless sensor batteries last?
Many LoRaWAN sensors last several years, depending on reporting interval and temperature. Sensors inside cold rooms drain faster.
Can it share our existing network monitoring?
Yes. SNMP- or MQTT-capable sensors can feed the Zabbix you already use for the network.
相关指南
湿热气候机房检查清单:供电、制冷、安防与布线
我们在老挝新建或整改机房时实际使用的清单:电压不稳、空调故障、水浸、粉尘,以及没人写的文档。
网络监控入门:在用户来电之前发现问题
该监控什么,SNMP、syslog 和 NetFlow 各自用途,如何告警而不让团队疲于奔命,以及老挝中型机构如何起步。
正确选型 UPS:VA、瓦数、功率因数与真实电池续航
为什么有些 3 kVA UPS 只能带 1,800 W,后备式、在线互动式与在线式如何选择,如何实事求是估算续航,以及 UPS 如何与发电机配合。
矿用卡车 GPS 车队定位:信号覆盖、油耗、司机与平台
为信号不稳定省份的重型卡车选择 GPS 定位终端:断点续传、油位传感器、CAN 总线、司机身份识别、电子围栏和数据保存。
相关解决方案
智能楼宇与 IoT
发给我们建筑平面图或几张现场照片
我们会先询问一些细节,再给出初步设计方案。首次咨询免费,可用老挝语、泰语或英语,通过 WhatsApp 或 Facebook 主页联系。